Cooling & AC

AC Size Calculator

An air conditioner needs about 20 BTU per hour for each square foot of floor area. Enter the room size and the AC size calculator picks the right air conditioner BTU and tonnage, adjusted for ceiling height, sun, people, kitchen use and insulation, using the ENERGY STAR sizing chart.

Sun exposure
Insulation condition
Formula with your numbers:

Sun, people and kitchen adjustments come from ENERGY STAR. Ceiling height and insulation are rule-of-thumb adjustments.

Recommended air conditioner

—
BTU/hr
Your room and the right AC size

Room drawn to scale · sizes compared to your load

How to Size an Air Conditioner

To size an air conditioner, multiply the room's square footage by 20 BTU/hr, then adjust for sun, people and kitchen use. There are 5 steps:

  1. Measure the room length and width in feet and multiply them to get square feet. 1 m² equals 10.76 sq ft.
  2. Find the base size on the ENERGY STAR chart, or multiply the area by 20.
  3. Adjust for sun: add 10% for a very sunny room or remove 10% for a heavily shaded room.
  4. Add 600 BTU/hr for each regular occupant beyond 2, and 4,000 BTU/hr if the room includes a kitchen.
  5. Pick the nearest standard size at or just above the result.
AC BTU/hr ≈ sq ft × 20 × sun + 600 × (people − 2) + kitchen

Ceilings above 8 ft (2.4 m) add air volume. A 10 ft ceiling holds 25% more air than an 8 ft ceiling, so the AC size calculator scales the load by ceiling height ÷ 8.

Worked example

A sunny 20 × 15 ft living room (300 sq ft, 27.9 m²) used by 3 people:

  1. 300 sq ft falls in the ENERGY STAR 300 to 350 sq ft row: 8,000 BTU/hr.
  2. Very sunny: 8,000 × 1.1 = 8,800 BTU/hr.
  3. 1 extra person: 8,800 + 600 = 9,400 BTU/hr.

The right pick is a 10,000 BTU/hr window air conditioner.

ENERGY STAR Air Conditioner Size Chart

ENERGY STAR (EnergyStar.gov) lists the cooling capacity a room air conditioner needs for each room size. The row for your room is highlighted.

Area (sq ft)Area (m²)Capacity (BTU/hr)Tons
100 to 1509 to 145,0000.42
150 to 25014 to 236,0000.50
250 to 30023 to 287,0000.58
300 to 35028 to 338,0000.67
350 to 40033 to 379,0000.75
400 to 45037 to 4210,0000.83
450 to 55042 to 5112,0001.00
550 to 70051 to 6514,0001.17
700 to 1,00065 to 9318,0001.50
1,000 to 1,20093 to 11121,0001.75
1,200 to 1,400111 to 13023,0001.92
1,400 to 1,500130 to 13924,0002.00
1,500 to 2,000139 to 18630,0002.50
2,000 to 2,500186 to 23234,0002.83

How Many BTU to Cool a Room

Common room and home sizes with the ENERGY STAR cooling capacity.

AreaTypical spaceBTU/hr
150 sq ft (14 m²)Small bedroom or office6,000
300 sq ft (28 m²)Large bedroom8,000
500 sq ft (46 m²)Living room or studio12,000
800 sq ft (74 m²)Open-plan living and kitchen18,000
1,000 sq ft (93 m²)Small apartment21,000
1,500 sq ft (139 m²)Small house30,000
2,000 sq ft (186 m²)Medium house34,000

Window, Portable, Mini Split or Central Air?

There are 4 main air conditioner types, and each one fits a different size range.

TypeTypical capacityBest for
Window air conditioner5,000 to 25,000 BTU/hrOne room up to about 1,000 sq ft (93 m²). Lowest cost per BTU.
Portable air conditioner5,000 to 12,000 BTU/hr (SACC)One room where a window unit does not fit. Size by the SACC rating, not the ASHRAE rating.
Ductless mini split6,000 to 36,000 BTU/hr per headSingle rooms, additions and garage conversions. Quiet, efficient, also heats.
Central air conditioner18,000 to 60,000 BTU/hr (1.5 to 5 tons)Whole homes with ducts. Needs a Manual J load calculation.

Portable air conditioner boxes show an ASHRAE rating and a lower DOE SACC rating. Match the SACC number to the AC size calculator result. A unit sold as "14,000 BTU (ASHRAE)" often delivers about 10,000 BTU/hr (SACC).

How to Find the BTU of Your Air Conditioner

The BTU of an air conditioner is printed on the nameplate as "cooling capacity" in BTU/hr. There are 3 other ways to find it:

  1. Model number. Central air conditioner and heat pump model numbers often contain 18, 24, 30, 36, 42, 48 or 60, which is the size in thousands of BTU/hr.
  2. Tons. Multiply the tonnage by 12,000. A 2.5-ton unit is 30,000 BTU/hr.
  3. Watts. Multiply the electrical input in watts by the energy efficiency ratio (EER). An 800 W window unit with an EER of 11 delivers about 8,800 BTU/hr.

Model number decoder

Watts × EER

Why the Right AC Size Matters

A correctly sized air conditioner cools the room evenly, removes humidity and uses the least electricity. A wrong size causes 2 different problems:

  • Oversized units cool the air too fast and switch off before removing moisture. The room feels cold and clammy, the compressor short-cycles, and lifespan drops.
  • Undersized units run nonstop on hot days, never reach the thermostat setting and raise utility bills.

Pick the closest standard size at or just above your calculated load. For a whole house, ask a licensed HVAC contractor for a Manual J load calculation, which accounts for insulation R-values, window area and orientation, air leakage and local climate.

Which Sizing Calculator Do I Need?

The four sizing calculators use the same ENERGY STAR and climate data but answer different questions. Pick the one that matches yours.

CalculatorUse it when you are…What it gives you
AC Size Calculator (this page)Buying an air conditioner for one spaceThe cooling BTU and tonnage, the standard unit size to buy and its running watts (SEER2)
Heating BTU CalculatorSizing a furnace or boiler for a whole houseThe heating load by climate zone and the furnace input BTU at your AFUE
Room BTU CalculatorSeveral rooms, or one room in metresCooling and heating per room, the whole-home total and a mini-split head for each room
BTU per Square FootChecking a rule of thumb or a unit you already ownHow many sq ft a BTU rating covers, and BTU per sq ft by climate and type of space

AC Size Calculator FAQs

How many BTU do I need to cool 500 sq ft?

A 500 sq ft (46 m²) room needs a 12,000 BTU/hr air conditioner. ENERGY STAR lists 12,000 BTU/hr for 450 to 550 sq ft.

How many BTU do I need to cool 800 sq ft?

An 800 sq ft (74 m²) space needs about 18,000 BTU/hr of cooling. ENERGY STAR lists 18,000 BTU/hr for 700 to 1,000 sq ft.

How many BTU do I need to cool 1,000 sq ft?

A 1,000 sq ft (93 m²) space needs 18,000 to 21,000 BTU/hr of cooling, which is 1.5 to 1.75 tons.

What size AC do I need for a 12×12 room?

A 12 × 12 ft room (144 sq ft, 13.4 m²) needs a 5,000 BTU/hr air conditioner. Add 10% for a very sunny room.

Where do I find the BTU on my air conditioner?

The BTU is printed on the label (nameplate) on the side or back of the unit, listed as "cooling capacity". On a window unit, look on the side panel or behind the front grille. Central air conditioner model numbers often include the size in thousands of BTU/hr, such as 024 for 24,000 BTU/hr.

Is it bad to oversize an air conditioner?

Yes, an oversized air conditioner short-cycles, removes less humidity and wears out faster. Pick the closest size at or just above the calculated load.