Gas & Fuel
Gas Appliance BTU Chart
Typical home gas appliances use 5,000 to 200,000 BTU/hr; the total of all of them sets the gas meter and pipe size. Tick the appliances in your home and adjust each rating. The calculator totals BTU/hr, natural gas CFH and propane gallons per hour.
Total connected load
Biggest users first
Typical Gas Appliance BTU Ratings
Ratings are typical input ranges for U.S. homes. Your appliance's rating plate is the value to use.
| Appliance | Low | High | Typical | Natural gas CFH |
|---|---|---|---|---|
| Furnace | 40,000 | 120,000 | 80,000 | 77 |
| Boiler | 50,000 | 200,000 | 100,000 | 97 |
| Tank water heater (40–50 gal) | 30,000 | 50,000 | 40,000 | 39 |
| Tankless water heater | 120,000 | 199,000 | 199,000 | 192 |
| Range top burner (each) | 5,000 | 18,000 | 9,000 | 9 |
| Oven | 16,000 | 30,000 | 25,000 | 24 |
| Full range (4 burners + oven) | 45,000 | 75,000 | 65,000 | 63 |
| Clothes dryer | 20,000 | 35,000 | 22,000 | 21 |
| Fireplace insert / log set | 20,000 | 60,000 | 30,000 | 29 |
| Patio heater | 30,000 | 48,000 | 40,000 | 39 |
| Outdoor grill | 25,000 | 60,000 | 40,000 | 39 |
| Garage heater | 30,000 | 80,000 | 45,000 | 43 |
| Pool heater | 100,000 | 400,000 | 250,000 | 241 |
| Space heater (vent-free) | 6,000 | 30,000 | 20,000 | 19 |
| Outdoor fire pit | 40,000 | 100,000 | 65,000 | 63 |
| Outdoor propane burner / fryer | 50,000 | 200,000 | 100,000 | 97 |
| Generator (whole house) | 150,000 | 300,000 | 200,000 | 193 |
Why You Should Not Raise a Burner's BTU
Each appliance is certified at its rated input. Burner BTU is set by the orifice size and the manifold gas pressure. Drilling an orifice or raising pressure can cause incomplete combustion, soot and carbon monoxide. Converting between natural gas and propane, or changing input, is a job for a qualified gas technician using the maker's conversion kit.
Gas Appliance BTU FAQs
How many BTU is a gas fire pit or outdoor propane burner?
Outdoor gas fire pits are typically 40,000 to 100,000 BTU/hr; outdoor propane burners and fryers run about 50,000 to 200,000 BTU/hr. Check the rating plate for your model.
How do I increase the BTU on a fire pit or propane burner?
You can't safely raise it beyond the appliance's rating. Low flame is usually a partly closed valve, a blocked orifice, a frozen or undersized regulator, or a nearly empty tank. A high-pressure regulator is only for burners designed for it.
How many BTU does a gas stove use?
A home gas range uses about 45,000 to 75,000 BTU/hr with every burner and the oven on. Single burners run 5,000 to 18,000 BTU/hr.
How many BTU does a gas water heater use?
A 40 to 50 gallon gas tank water heater uses 30,000 to 50,000 BTU/hr; a whole-house tankless unit uses up to 199,000 BTU/hr.
How do I find the BTU of my gas appliance?
Read the rating plate. It lists the input in BTU/hr, usually inside the access panel, on the back, or under the cooktop.
Can I increase the BTU on my gas appliance?
No, not on your own. Burner input is set by the orifice size and gas pressure. Changing it needs a qualified gas technician and must match the maker's rating.