Heating & Room Sizing
Furnace Size Calculator
To size a furnace, multiply square footage by 30 to 60 BTU per sq ft for your climate, then divide by the furnace AFUE to get the input BTU. A 1,500 sq ft home in a cold climate needs about 70,000 BTU/hr of heat, which is a 75,000 to 80,000 BTU input furnace at 95% AFUE.
Furnace input size
Output = input × AFUE
How to Size a Furnace
Furnace sizing has 4 steps:
- Multiply heated square footage by the climate factor (low end for good insulation, high end for poor).
- Scale for ceilings above 8 ft.
- Divide the heating load by the AFUE to get input BTU/hr.
- Pick the nearest standard input size at or above the result: 40, 60, 70, 80, 100 or 120 thousand BTU/hr.
Oversized furnaces short-cycle, wear out sooner and leave uneven heat. A Manual J load calculation and Manual S equipment selection give the exact size.
Furnace model number decoder
Many brands put the input BTU in thousands as a 3-digit block (040, 060, 080, 100, 120). Always confirm on the rating plate.
Furnace Size Chart by Home Size
Heating load in BTU/hr (average insulation, 8 ft ceilings). Divide by AFUE for input size.
| Home size | Zone 1 | Zone 2 | Zone 3 | Zone 4 | Zone 5 |
|---|---|---|---|---|---|
| 1,000 sq ft | 30,000–35,000 | 35,000–40,000 | 40,000–45,000 | 45,000–50,000 | 50,000–60,000 |
| 1,200 sq ft | 36,000–42,000 | 42,000–48,000 | 48,000–54,000 | 54,000–60,000 | 60,000–72,000 |
| 1,500 sq ft | 45,000–52,500 | 52,500–60,000 | 60,000–67,500 | 67,500–75,000 | 75,000–90,000 |
| 1,800 sq ft | 54,000–63,000 | 63,000–72,000 | 72,000–81,000 | 81,000–90,000 | 90,000–108,000 |
| 2,000 sq ft | 60,000–70,000 | 70,000–80,000 | 80,000–90,000 | 90,000–100,000 | 100,000–120,000 |
| 2,500 sq ft | 75,000–87,500 | 87,500–100,000 | 100,000–112,500 | 112,500–125,000 | 125,000–150,000 |
| 3,000 sq ft | 90,000–105,000 | 105,000–120,000 | 120,000–135,000 | 135,000–150,000 | 150,000–180,000 |
Furnace Size FAQs
What size furnace do I need for 1,500 sq ft?
A 1,500 sq ft home has a heating load of about 45,000 to 90,000 BTU/hr (zone 1 to zone 5), which means about 47,000 to 113,000 BTU/hr of furnace input at 95% to 80% AFUE (input = load ÷ AFUE). In zone 4 with a 95% furnace, that is about 75,000 BTU/hr input.
What size furnace do I need for 2,000 sq ft?
A 2,000 sq ft home has a heating load of about 60,000 to 120,000 BTU/hr, which means about 63,000 to 150,000 BTU/hr of furnace input at 95% to 80% AFUE. In a cold climate with a 95% furnace, about 100,000 BTU/hr input.
How do I find the BTU of my furnace?
The furnace BTU is on the rating plate inside the burner door, listed as input and output BTU/hr. Model numbers often include the input in thousands, such as 060 or 080.
What is the difference between furnace input and output BTU?
Input BTU is the fuel burned; output BTU is the heat delivered. Output = input × AFUE. An 80,000 BTU furnace at 80% AFUE delivers 64,000 BTU/hr.
How do I convert furnace BTU to tons?
Divide the furnace output BTU/hr by 12,000 to compare with AC tons. The furnace blower must also move enough air for the AC: about 400 CFM per ton.