To size a furnace, multiply square footage by 30 to 60 BTU per sq ft for your climate, then divide by the furnace AFUE to get the input BTU. A 1,500 sq ft home in a cold climate needs about 70,000 BTU/hr of heat, which is a 75,000 to 80,000 BTU input furnace at 95% AFUE.

Insulation and windows
Formula with your numbers:

Furnace input size

—
Furnace sizes vs your heating load

Output = input × AFUE

How to Size a Furnace

Furnace sizing has 4 steps:

  1. Multiply heated square footage by the climate factor (low end for good insulation, high end for poor).
  2. Scale for ceilings above 8 ft.
  3. Divide the heating load by the AFUE to get input BTU/hr.
  4. Pick the nearest standard input size at or above the result: 40, 60, 70, 80, 100 or 120 thousand BTU/hr.
Input BTU/hr = sq ft × zone factor ÷ AFUE

Oversized furnaces short-cycle, wear out sooner and leave uneven heat. A Manual J load calculation and Manual S equipment selection give the exact size.

Furnace model number decoder

Many brands put the input BTU in thousands as a 3-digit block (040, 060, 080, 100, 120). Always confirm on the rating plate.

Furnace Size Chart by Home Size

Heating load in BTU/hr (average insulation, 8 ft ceilings). Divide by AFUE for input size.

Home sizeZone 1Zone 2Zone 3Zone 4Zone 5
1,000 sq ft30,000–35,00035,000–40,00040,000–45,00045,000–50,00050,000–60,000
1,200 sq ft36,000–42,00042,000–48,00048,000–54,00054,000–60,00060,000–72,000
1,500 sq ft45,000–52,50052,500–60,00060,000–67,50067,500–75,00075,000–90,000
1,800 sq ft54,000–63,00063,000–72,00072,000–81,00081,000–90,00090,000–108,000
2,000 sq ft60,000–70,00070,000–80,00080,000–90,00090,000–100,000100,000–120,000
2,500 sq ft75,000–87,50087,500–100,000100,000–112,500112,500–125,000125,000–150,000
3,000 sq ft90,000–105,000105,000–120,000120,000–135,000135,000–150,000150,000–180,000

Furnace Size FAQs

What size furnace do I need for 1,500 sq ft?

A 1,500 sq ft home has a heating load of about 45,000 to 90,000 BTU/hr (zone 1 to zone 5), which means about 47,000 to 113,000 BTU/hr of furnace input at 95% to 80% AFUE (input = load ÷ AFUE). In zone 4 with a 95% furnace, that is about 75,000 BTU/hr input.

What size furnace do I need for 2,000 sq ft?

A 2,000 sq ft home has a heating load of about 60,000 to 120,000 BTU/hr, which means about 63,000 to 150,000 BTU/hr of furnace input at 95% to 80% AFUE. In a cold climate with a 95% furnace, about 100,000 BTU/hr input.

How do I find the BTU of my furnace?

The furnace BTU is on the rating plate inside the burner door, listed as input and output BTU/hr. Model numbers often include the input in thousands, such as 060 or 080.

What is the difference between furnace input and output BTU?

Input BTU is the fuel burned; output BTU is the heat delivered. Output = input × AFUE. An 80,000 BTU furnace at 80% AFUE delivers 64,000 BTU/hr.

How do I convert furnace BTU to tons?

Divide the furnace output BTU/hr by 12,000 to compare with AC tons. The furnace blower must also move enough air for the AC: about 400 CFM per ton.