Heating & Room Sizing

Heating BTU Calculator

A home needs 30 to 60 BTU per hour of heat for each square foot, depending on climate and insulation. Enter the area, climate and insulation, and the heating BTU calculator returns the heating load and the furnace input size for your AFUE.

Climate
Insulation condition
Formula with your numbers:

Rule-of-thumb estimate. A Manual J load calculation sizes a whole-house furnace or heat pump exactly.

Heating load

—
Your space and the right furnace

Room drawn to scale · furnace output vs your load

How to Calculate Heating BTU

To calculate heating BTU, multiply the heated square footage by the BTU-per-square-foot factor for your climate, then adjust for insulation and ceiling height.

Heating BTU/hr = sq ft × climate factor × insulation × (ceiling ÷ 8)

To size a furnace, divide the heating load by the furnace efficiency (AFUE). Furnaces are sold by input BTU, and output BTU = input × AFUE.

Furnace input BTU/hr = heating load ÷ AFUE

Worked example

A 1,500 sq ft (139 m²) house in Boston with average insulation and 8 ft ceilings:

  1. 1,500 × 45 = 67,500 BTU/hr heating load
  2. 67,500 ÷ 0.95 AFUE = 71,053 BTU/hr input
  3. Nearest standard size: 80,000 BTU/hr input (76,000 BTU/hr output)

How Many BTU to Heat a House: Chart

Heating BTU/hr by floor area and climate. Your area and climate are highlighted.

AreaHot
Houston, Miami
Warm
Atlanta, Dallas
Moderate
Nashville, DC
Cold
Boston, Chicago
Very cold
Minneapolis, Alaska
400 sq ft (37 m²)12,00014,00016,00018,00022,000
500 sq ft (46 m²)15,00017,50020,00022,50027,500
600 sq ft (56 m²)18,00021,00024,00027,00033,000
800 sq ft (74 m²)24,00028,00032,00036,00044,000
1,000 sq ft (93 m²)30,00035,00040,00045,00055,000
1,200 sq ft (111 m²)36,00042,00048,00054,00066,000
1,500 sq ft (139 m²)45,00052,50060,00067,50082,500
1,800 sq ft (167 m²)54,00063,00072,00081,00099,000
2,000 sq ft (186 m²)60,00070,00080,00090,000110,000
2,400 sq ft (223 m²)72,00084,00096,000108,000132,000
3,000 sq ft (279 m²)90,000105,000120,000135,000165,000

What Changes the Heating BTU You Need

There are 6 factors that raise or lower heating BTU:

  1. Climate. The colder the winter design temperature, the higher the factor. Alaska homes need nearly twice the BTU per sq ft of Houston homes.
  2. Insulation. Attic insulation, wall R-value and double-glazed windows cut heat loss by 15% or more.
  3. Air leakage. Drafts around doors, windows and attic hatches can add 20% to the heating load in older homes.
  4. Ceiling height. A 10 ft ceiling holds 25% more air than an 8 ft ceiling.
  5. Windows. Single-pane glass loses about twice the heat of double-glazed windows.
  6. Basement and slab. Unheated basements and uninsulated slabs pull heat from the floor above.

Which Sizing Calculator Do I Need?

The four sizing calculators use the same ENERGY STAR and climate data but answer different questions. Pick the one that matches yours.

CalculatorUse it when you are…What it gives you
AC Size CalculatorBuying an air conditioner for one spaceThe cooling BTU and tonnage, the standard unit size to buy and its running watts (SEER2)
Heating BTU Calculator (this page)Sizing a furnace or boiler for a whole houseThe heating load by climate zone and the furnace input BTU at your AFUE
Room BTU CalculatorSeveral rooms, or one room in metresCooling and heating per room, the whole-home total and a mini-split head for each room
BTU per Square FootChecking a rule of thumb or a unit you already ownHow many sq ft a BTU rating covers, and BTU per sq ft by climate and type of space

Heating BTU FAQs

How many BTU does it take to heat 1,000 sq ft?

Heating 1,000 sq ft (93 m²) takes 30,000 to 55,000 BTU/hr, from 30 BTU/hr per sq ft in a hot climate to 55 in a very cold one. A moderate climate needs about 40,000 BTU/hr.

How many BTU does it take to heat 1,500 sq ft?

Heating 1,500 sq ft (139 m²) takes 45,000 to 82,500 BTU/hr. A cold climate such as Boston needs about 67,500 BTU/hr.

How many BTU does it take to heat 2,000 sq ft?

Heating 2,000 sq ft (186 m²) takes 60,000 to 110,000 BTU/hr, about 80,000 BTU/hr in a moderate climate.

How many BTU does it take to heat 500 sq ft?

Heating 500 sq ft (46 m²) takes 15,000 to 27,500 BTU/hr, about 20,000 BTU/hr in a moderate climate.

What size furnace do I need?

Pick a furnace whose output (input BTU × AFUE) matches your heating load. A 60,000 BTU/hr heating load needs an 80,000 BTU input furnace at 80% AFUE or a 70,000 BTU input furnace at 95% AFUE.