Water & Temperature

Hot Water Cylinder Size Calculator

A hot water cylinder needs about 45 litres per person stored at 60°C, plus about 25% more if a heat pump heats it to 50°C. Enter the number of people and bathrooms and how the water is heated. The calculator picks a standard cylinder size and shows the energy, BTU, heat-up time and cost to heat it.

Heated by
Formula with your numbers:

Default prices are the Ofgem price cap averages for 1 October to 31 December 2026 (electricity 26.32p, gas 7.97p per kWh). Heat-up time ignores standing losses, so allow 10% to 20% longer in practice.

Recommended cylinder

—
Standard cylinder sizes vs your household

Litres of stored hot water

How to Size a Hot Water Cylinder

  1. Litres: people × 45 L, plus about 30 L for each extra bathroom.
  2. Heat pump: multiply by 1.25, because water stored at 50°C holds 25% less heat than at 60°C.
  3. Round up to the next standard size: 120, 150, 170, 180, 210, 250 or 300 litres.
  4. Energy to heat it: litres × 4.186 × (stored temp − 10°C) ÷ 3,600 = kWh. Multiply by 3,412 for BTU.
kWh = litres × 4.186 × ΔT ÷ 3,600 · time (h) = kWh ÷ heat input kW

Worked example

A family of 4 with one bathroom and a 3 kW immersion heater:

  1. 4 × 45 = 180 L, so a 180 litre cylinder
  2. Energy from 10°C to 60°C: 180 × 4.186 × 50 ÷ 3,600 = 10.5 kWh (35,700 BTU)
  3. Heat-up time: 10.5 ÷ 3 = 3.5 hours
  4. Cost: 10.5 × 26.32p = £2.75 from cold

Hot Water Cylinder Size Chart

HouseholdGas or immersion (60°C)Heat pump (50°C)Energy to heat (60°C)
1 person, 1 bathroom90 L90 L5.2 kWh
2 people, 1 bathroom90 L120 L5.2 kWh
3 people, 1 bathroom150 L170 L8.7 kWh
4 people, 1 bathroom180 L250 L10.5 kWh
4 people, 2 bathrooms210 L250 L12.2 kWh
5 people, 2 bathrooms250 L300 L14.5 kWh
6 people, 3 bathrooms300 L300 L17.4 kWh

Hot Water Cylinder FAQs

What size hot water cylinder do I need for 4 people?

About 180 litres for 4 people with one bathroom (4 × 45 L), or 210 litres with two bathrooms. With a heat pump, which stores water at about 50°C instead of 60°C, go up to about 250 litres.

How long does a 150 litre cylinder take to heat with an immersion heater?

About 2 hours 54 minutes with a 3 kW immersion heater, from 10°C to 60°C: 150 × 4.186 × 50 ÷ 3,600 = 8.7 kWh, and 8.7 ÷ 3 = 2.9 hours.

How much does it cost to heat a hot water cylinder?

About £2.30 to heat 150 litres from cold with an immersion heater at 26.32p per kWh (8.7 kWh). With a gas boiler at 7.97p per kWh and 90% efficiency it is about 77p.

Why does a heat pump need a bigger cylinder?

Heat pumps run most efficiently storing water at about 50°C instead of 60°C, so each litre holds less heat. (60 − 10) ÷ (50 − 10) = 1.25, so the cylinder needs to be about 25% bigger for the same hot water.

How many BTU does it take to heat a hot water cylinder?

A 150 litre cylinder heated from 10°C to 60°C takes 8.7 kWh, which is about 29,800 BTU. 1 kWh = 3,412 BTU.

Related Calculators

More Water & Temperature Calculators

About the author

Muhammad Asim

Muhammad Asim founded The BTU Calculator. He builds every calculator, writes the pages, and checks each number against the site's shared formulas and named sources such as NIST, the U.S. EIA, ENERGY STAR and ASHRAE.

Who runs this site · How we calculate · Editorial policy · X (Twitter)