Heating & Room Sizing

Heat Pump Size Calculator

Size a heat pump to the larger of the cooling load and the heating load divided by the share of capacity it keeps at your coldest design temperature. Enter the floor area, your climate and the type of heat pump. The calculator compares heating and cooling, accounts for capacity loss in cold weather and shows the backup heat and the balance point.

Climate (heating BTU/hr per sq ft · design temperature)
Formula with your numbers:

Capacity and COP in the cold are typical planning figures (standard units keep about 55% of their 47°F rating at 5°F, cold-climate units about 85%, ground source 100%). Use the maker's data at your design temperature and a Manual J load for the final choice.

Heat pump size (rated at 47°F)

—
Heat pump output vs house heat loss

By outdoor temperature · the balance point is where they cross

How to Size a Heat Pump

  1. Heating load: floor area × the climate factor (30 to 55 BTU/hr per sq ft), or a Manual J result.
  2. Cooling load: the ENERGY STAR chart, about 20 BTU/hr per sq ft.
  3. Capacity at design temperature: find the share of its rating the heat pump keeps at your coldest design temperature.
  4. Rated size needed = the larger of the cooling load and heating load ÷ that share. Round up to the next ½-ton size.
Rated BTU/hr = max(cooling load, heating load ÷ capacity share at design temp)

Worked example

2,000 sq ft in a moderate climate (40 BTU/hr per sq ft, design 15°F) with a cold-climate heat pump:

  1. Heating load: 2,000 × 40 = 80,000 BTU/hr
  2. Capacity share at 15°F: 85% + (100% − 85%) × (15 − 5) ÷ 42 ≈ 89%
  3. Rated size for heating: 80,000 ÷ 0.89 ≈ 90,000 BTU/hr, more than the largest 5-ton home unit
  4. So: a 5-ton (60,000 BTU/hr) heat pump carries the house down to its balance point, with about 27,000 BTU/hr (8 kW) of backup heat on the design night. Cooling needs only about 34,000 BTU/hr (2.8 tons).

Heat Pump Size Chart

Rated tons needed for heating with a cold-climate heat pump (85% at 5°F), before rounding, and the cooling tons for comparison. Rows over 5 tons need two units or backup heat.

AreaCooling tonsHot (40°F)Warm (25°F)Moderate (15°F)Cold (5°F)Very cold (-10°F)
1,000 sq ft1.72.63.23.84.46.5
1,500 sq ft2.53.84.75.66.69.8
2,000 sq ft3.35.16.37.58.813.1
2,500 sq ft4.26.47.99.411.016.4
3,000 sq ft5.07.79.511.313.219.6

Heat Pump Size FAQs

What size heat pump do I need for 2,000 sq ft?

About 3 tons for cooling, but 5 tons plus backup heat for heating in a moderate climate. 2,000 sq ft at 40 BTU/hr per sq ft is 80,000 BTU/hr on a 15°F design night. A cold-climate heat pump keeps about 89% of its rating at 15°F (85% at 5°F), so heating alone would need about 90,000 BTU/hr of rating, more than a 5-ton (60,000 BTU/hr) unit. A 5-ton unit plus about 27,000 BTU/hr of backup heat covers it. Cooling needs about 34,000 BTU/hr (2.8 tons).

Should I size a heat pump for heating or cooling?

For heating in cold climates, for cooling in hot ones. The calculator takes the larger of the two: the cooling load from the ENERGY STAR chart, or the heating load divided by the share of capacity the heat pump keeps at your design temperature.

Why does a heat pump lose capacity in the cold?

The colder the outdoor air, the less heat the refrigerant can pull from it. A standard air-source unit may deliver only about half its rated output at 5°F, while cold-climate models keep around 70% to 100%. Check the maker's capacity table at your design temperature.

What is a heat pump balance point?

The outdoor temperature where the heat pump's output equals the house's heat loss. Below it, backup heat (electric strips or a furnace) makes up the difference. The chart on this page shows where your balance point falls.

How do I convert heat pump tons to kW?

1 ton = 12,000 BTU/hr = 3.517 kW of heat or cooling. A 3-ton heat pump is about 10.5 kW. Its electrical input is lower: output ÷ COP.

Related Calculators

More Heating & Room Sizing Calculators

About the author

Muhammad Asim

Muhammad Asim founded The BTU Calculator. He builds every calculator, writes the pages, and checks each number against the site's shared formulas and named sources such as NIST, the U.S. EIA, ENERGY STAR and ASHRAE.

Who runs this site · How we calculate · Editorial policy · X (Twitter)